Initial list of faults

Faults can be gathered by enabling SNMP and installing some opensource tool to catch and poll SNMP. When using for example Zabbix one can also put agent running on host to catch any other fault. Here is some initial list of high level faults and how they can be caught. List assumes that one enables usage of SNMP and then would use tool like Zabbix. There is also Pacemaker mentioned if used. Usage of that is limited to number of nodes, so it works better only for controller nodes.

Raw faults How to detect Effected virtual resource Actions to recover
Where Description Severity Method Comment
chassis Blade not present SNMP
Chassis fan degraded Warning SNMP
Chassis fan failed SNMP
Chassis fan not present SNMP
Chassis manager degraded SNMP
Chassis manager failed SNMP
Chassis manager not present SNMP
Chassis power degraded SNMP
Chassis power failed SNMP
Chassis power input line status error SNMP
Chassis power not present SNMP
Chassis removal SNMP
Network connector not present SNMP
disk array Disk array error SNMP
libvirt State of a virtual machine has changed SNMP
openstack Openstack service is in failed state such as nova-compute zabbix agent
Openstack status zabbix agent
Openvswitch daemon is not in active state zabbix agent
Openvswitch status zabbix agent
os Available memory too low zabbix agent
Free FS space is less than 10% on volume {#FSNAME} zabbix agent
Host information has changed zabbix agent
Processor load too high zabbix agent
System has restarted zabbix agent
Zabbix agent is unreachable
pacemaker Corosync is not in active state SNMP controller node, as limited?
Pacemaker is not in active state SNMP controller node, as limited?
Pacemaker node {#NODENAME} status has changed on {HOST.NAME} SNMP controller node, as limited?
Pacemaker PCS daemon is not in active state SNMP controller node, as limited?
Pacemaker resource {#RESOURCENAME} status has changed on {HOST.NAME} SNMP controller node, as limited?
server Cold start SNMP
Cpu condition not ok SNMP
Fan degraded SNMP
Fan failed SNMP
Fan not present SNMP
Fan redundancy lost SNMP
HW SNMP agent authentication failure SNMP
Network adapter connectivity lost SNMP
Memory condition not ok SNMP
POST error SNMP
Power degraded SNMP
Power failed Critical SNMP
Power not present Critical SNMP
Power redundancy lost Warning SNMP
Power threshold exceeded Warning SNMP
security override engaged SNMP
self test error SNMP
Server power off Critical SNMP
Server power on SNMP
Server power on failure SNMP
Server reset SNMP
Temperature status degraded Warning SNMP
Thermal condition not ok Warning SNMP
Thermal confirmation SNMP Up again after thermal shudown
switch Link down Critical SNMP
Link up Info SNMP

Describing faults

Many of the faults needs to be configurable while others not. Hardware faults especially might need different triggers in different HW while some OpenStack internal fault will always be caught the same way.