User Tools

Site Tools


get_started:intel_pod2

Introduction

Intel POD 2 is currently assigned to CPERF. CPERF is focused on SDN controller performance testing. More information may be found at the CPERF project proposal page.

Requirements

TBD

Systems

Hostname CPU Model Memory Storage IPMI: IP/MAC, U/P 1GbE: NIC#, IP, MAC, VLAN, Network 10GbE: NIC#, IP, MAC, VLAN, Network Note
pod2-jp-jump 2xE5-2690 48GB 240GB (SSD)
1TB (SATA)
IF0: 10.2.117.35
00:1E:67:4F:B7:B3
U/P: root/root
IF0: 10.2.117.36
00:1E:67:4F:B7:B1
VLAN 984 (untagged)
DMZ
IF1: 10.2.1.1
00:1E:67:4F:B7:B2
VLAN 201 (untagged)
Admin
IF2: 10.2.12.1
00:1B:21:44:F1:B4
VLAN 202 (untagged)
Private
10.2.14.1
VLAN 204 (tagged)
Management
IF3: 10.2.13.1
00:1B:21:44:F1:B5
VLAN 203 (untagged)
Storage
10.2.15.1
VLAN 205 (untagged)
Public
pod2-jp-node1 2xE5-2690 48GB 2TB (SATA) IF0: 10.2.117.37
00:1E:67:4F:CC:0D
U/P: root/root
IF0: 10.2.117.38
00:1E:67:4F:CC:0B
VLAN 984 (untagged)
DMZ
IF1: 10.2.1.2
00:1E:67:4F:CC:0C
VLAN 201 (untagged)
Admin
IF2: 10.2.12.2
90:E2:BA:47:AA:64
VLAN 202 (untagged)
Private
10.2.14.2
VLAN 204 (tagged)
Management
IF3: 10.2.13.2
90:E2:BA:47:AA:65
VLAN 203 (untagged)
Storage
10.2.15.2
VLAN 205 (untagged)
Public
pod2-jp-node2 2xE5-2690 64GB 200GB (SSD)
1TB (SATA)
IF0: 10.2.117.39
00:1E:67:4F:CC:F3
U/P: root/root
IF0: 10.2.117.40
00:1E:67:4F:CC:F1
VLAN 984 (untagged)
DMZ
IF1: 10.2.1.2
00:1E:67:4F:CC:F2
VLAN 201 (untagged)
Admin
IF2: 10.2.12.3
00:1B:21:44:F0:14
VLAN 202 (untagged)
Private
10.2.14.3
VLAN 204 (tagged)
Management
IF3: 10.2.13.3
00:1B:21:44:F0:15
VLAN 203 (untagged)
Storage
10.2.15.3
VLAN 205 (untagged)
Public
pod2-jp-node3 2xE5-2690 48GB 2TB (SATA) IF0: 10.2.117.41
00:1E:67:4F:B9:57
U/P: root/root
IF0: 10.2.117.42
00:1E:67:4F:B9:55
VLAN 984 (untagged)
DMZ
IF1: 10.2.1.4
00:1E:67:4F:B9:56
VLAN 201 (untagged)
Admin
IF2: 10.2.12.4
00:1B:21:73:E7:FC
VLAN 202 (untagged)
Private
10.2.14.4
VLAN 204 (tagged)
Management
IF3: 10.2.13.4
00:1B:21:73:E7:FD
VLAN 203 (untagged)
Storage
10.2.15.4
VLAN 205 (untagged)
Public
pod2-gp-node4 2xE5-2680 64GB 2TB (SATA) IF0: 10.2.117.43
00:1E:67:B2:12:73
U/P: root/root
IF0: 10.2.117.42
00:1E:67:B2:12:6F
VLAN 984 (untagged)
DMZ
IF1: 10.2.1.5
00:1E:67:B2:12:70
VLAN 201 (untagged)
Admin
IF2: 10.2.12.5
00:1E:67:AC:31:C8
VLAN 202 (untagged)
Private
10.2.14.5
VLAN 204 (tagged)
Management
IF3: 10.2.13.5
00:1E:67:AC:31:C9
VLAN 203 (untagged)
Storage
10.2.15.5
VLAN 205 (untagged)
Public
pod2-gp-node5 2xE5-2680 64GB 2TB (SATA) IF0: 10.2.117.45
00:1E:67:B2:08:7F
U/P: root/root
IF0: 10.2.117.44
00:1E:67:B2:08:7B
VLAN 984 (untagged)
DMZ
IF1: 10.2.1.6
00:1E:67:B2:08:7C
VLAN 201 (untagged)
Admin
IF2: 10.2.12.6
00:1E:67:B5:4A:68
VLAN 202 (untagged)
Private
10.2.14.6
VLAN 204 (tagged)
Management
IF3: 10.2.13.6
00:1E:67:B5:4A:69
VLAN 203 (untagged)
Storage
10.2.15.6
VLAN 205 (untagged)
Public

VPN Users

Name Email Project Role Note
Daniel Farrell dfarrell@redhat.com CPERF Lead
Luis Gomez ecelgp@gmail.com CPERF Committer
Jamo Luhrsen jluhrsen@redhat.com CPERF Committer
Marcus Williams marcus.williams@intel.com CPERF Committer
Al Morton acmorton@att.com CPERF Committer

Firewall Rules

Port(s) Service Note
None

JIRA Issues

Issue Summary Status Note
None

Topology