User Tools

Site Tools


get_started:intel_pod8

Introduction

Intel POD 8 is current assigned to Compass4nfv. Compass4nfv is an installer project based on open source project Compass. More information can be found on the Compass Based OPNFV Installer Project Proposal page. Contacts are Meimei (Huawei) meimei@huawei.com, Justin chi (Huawei) chigang@huawei.com, Xuhan (Huawei) carey.xuhan@huawei.com

Requirements

Add an additional tagged VLAN (804) on IF2 and add an additional tagged VLAN (805) on IF3 for Public access. Configured the IP addresses of the gateway for the Public network to 10.8.15.254

Systems

Hostname CPU Model Memory Storage IPMI: IP/MAC, U/P 1GbE: NIC#, IP, MAC, VLAN, Network 10GbE: NIC#, IP, MAC, VLAN, Network Note
pod8-urb-jump 2xXeon-5680 32GB 2TB IF0: 10.2.117.125
00:15:17:AC:3D:52
U/P: root/root
IF0: 10.2.117.126
00:15:17:AC:3D:50
VLAN 984 (untagged)
DMZ
IF1: 10.8.1.1
00:15:17:AC:3D:51
VLAN 801 (untagged)
Admin
IF2: 10.8.12.1
90:E2:BA:8B:A4:D0
VLAN 802 (untagged)
Private
10.8.14.1
VLAN 804 (tagged)
Management
IF3: 10.8.13.1
90:E2:BA:8B:A4:D1
VLAN 803 (untagged)
Storage
10.8.15.1
VLAN 805 (tagged)
Public
pod8-wcp-node1 2xE5-2699 64GB 3TB IF0: 10.2.117.127
00:1E:67:D4:30:D5
U/P: root/root
IF0: 10.2.117.128
00:1E:67:D4:30:D1
VLAN 984 (untagged)
DMZ
IF1: 10.8.1.2
00:1E:67:D4:30:D2
VLAN 801 (untagged)
Admin
IF2: 10.8.12.2
00:1E:67:C5:5B:28
VLAN 802 (untagged)
Private
10.8.14.2
VLAN 804 (tagged)
Management
IF3: 10.8.13.2
00:1E:67:C5:5B:29
VLAN 803 (untagged)
Storage
10.8.15.2
VLAN 805 (tagged)
Public
pod8-wcp-node2 2xE5-2699 64GB 3TB IF0: 10.2.117.129
00:1E:67:D4:39:B8
U/P: root/root
IF0: 10.2.117.130
00:1E:67:D4:39:B4
VLAN 984 (untagged)
DMZ
IF1: 10.8.1.3
00:1E:67:D4:39:B5
VLAN 801 (untagged)
Admin
IF2: 10.8.12.3
00:1E:67:C5:52:24
VLAN 802 (untagged)
Private
10.8.14.3
VLAN 804 (tagged)
Management
IF3: 10.8.13.3
00:1E:67:C5:52:25
VLAN 803 (untagged)
Storage
10.8.15.3
VLAN 805 (tagged)
Public
pod8-wcp-node3 2xE5-2699 64GB 3TB IF0: 10.2.117.131
00:1E:67:D4:31:B5
U/P: root/root
IF0: 10.2.117.132
00:1E:67:D4:31:B1
VLAN 984 (untagged)
DMZ
IF1: 10.8.1.4
00:1E:67:D4:31:B2
VLAN 801 (untagged)
Admin
IF2: 10.8.12.4
00:1E:67:C1:FA:E0
VLAN 802 (untagged)
Private
10.8.14.4
VLAN 804 (tagged)
Management
IF3: 10.8.13.4
00:1E:67:C1:FA:E1
VLAN 803 (untagged)
Storage
10.8.15.4
VLAN 805 (tagged)
Public
pod8-wcp-node4 2xE5-2699 64GB 3TB IF0: 10.2.117.133
00:1E:67:D4:34:6A
U/P: root/root
IF0: 10.2.117.133
00:1E:67:D4:34:66
VLAN 984 (untagged)
DMZ
IF1: 10.8.1.5
00:1E:67:D4:34:67
VLAN 801 (untagged)
Admin
IF2: 10.8.12.5
00:1E:67:E2:58:80
VLAN 802 (untagged)
Private
10.8.14.5
VLAN 804 (tagged)
Management
IF3: 10.8.13.5
00:1E:67:E2:58:81
VLAN 803 (untagged)
Storage
10.8.15.5
VLAN 805 (tagged)
Public
pod8-wcp-node5 2xE5-2699 64GB 3TB IF0: 10.2.117.135
00:1E:67:D4:38:45
U/P: root/root
IF0: 10.2.117.136
00:1E:67:D4:38:41
VLAN 984 (untagged)
DMZ
IF1: 10.8.1.6
00:1E:67:D4:38:42
VLAN 801 (untagged)
Admin
IF2: 10.8.12.6
00:1E:67:C1:F9:2C\ VLAN 802 (untagged)
Private
10.8.14.6
VLAN 804 (tagged)
Management
IF3: 10.8.13.6
00:1E:67:C1:F9:2D
VLAN 803 (untagged)
Storage
10.8.15.5
VLAN 805 (tagged)
Public

VPN Users

Name Email Project Role Note
Fatih Degirmenci fatih.degirmenci@ericsson.com CI Stable Lead
Meimei meimei@huawei.com Compass Lead
Jose Lausuch jose.lausuch@ericsson.com Fuel Contributor
Morgan Richomme morgan.richomme@orange.com Functest Contributor

Firewall Rules

Port(s) Service Note
22, 443, 80 Jenkins CI
80, 443, 5222, 5223, 5228 Google-Base

JIRA Issues

Issue Summary Status Note
PHAROS-88 Intel Labs: investigate VLAN issue for Intel POD 8 In Progress

Topology

get_started/intel_pod8.txt · Last modified: 2016/02/08 18:42 by Jack Morgan